Energy Performance Assessment: Impact of Blind and Shading on Double Skin Facade Performance

Authors

  • Niloufar Ziasistani Department of Energy, University of Oviedo
  • Andrés Meana-Fernández Department of Energy, University of Oviedo
  • Antonio Jose Gutierrez-Trashorras Department of Energy, University of Oviedo

DOI:

https://doi.org/10.20868/ade.2025.5567

Keywords:

building energy savings, building energy performance assessment, double skin facade, design builder software

Abstract

The integration of blinds and an overhang within double skin facades (DSFs) presents an opportunity to enhance building energy performance significantly. This study investigates the impact of an inside blind and an overhang on DSF performance through simulations conducted on an office building in Madrid and Copenhagen using DesignBuilder software. The analysis compares scenarios with and without these solar control elements, considering parameters such as cooling and heating loads. Results show that integrating an internal blind within the DSF reduced annual cooling load by up to 16.4% in Copenhagen and 6.4% in Madrid. Furthermore, combining the overhang at variable angles with the blind results in additional cooling load reductions, with the 45° configuration proving to be the most effective strategy. Interestingly, shading strategies showed minimal impact on heating loads in moderate climates, with observed increases ranging from 0.8% to 3.3%. Overall, the findings highlight the potential of DSFs with integrated internal blinds and overhangs for optimizing building energy performance, particularly in moderate climates.

Downloads

Download data is not yet available.

References

1. Ascione, F., Bianco, N., Iovane, T., Mastellone, M., & Mauro, G.M. (2021). The evolution of building energy retrofit viadouble-skin and responsive façades: A review. SolarEnergy, 224, 703-717.https://doi.org/https://doi.org/10.1016/j.solener.2021.06.035

2. Lee, J., & Chang, J. D. (2015). Influence on Vertical Shading Device Orientation and Thickness on the Natural Ventilation and Acoustical Performance of a Double Skin Facade. Procedia Engineering, 118, 304-309. https://doi.org/https://doi.org/10.1016/j.proeng.2015.08.431

3. Zheng, C., Chen, C., Hong, X., Zhang, W., Yang, R., & Shi, F. (2024). Experimental evaluation of the thermal, lighting, and energy performances of a mechanically ventilated double-skin façade with Venetian blinds and a light shelf. Energy and Buildings, 306, 113947. https://doi.org/https://doi.org/10.1016/j.enbuild.2024.113947

4. Ziasistani, N., & Fazelpour, F. (2019). Comparative study of DSF, PV-DSF and PV-DSF/PCM building energy performance considering multiple parameters. Solar Energy, 187, 115-128. https://doi.org/https://doi.org/10.1016/j.solener.2019.05.040

Downloads

Published

2025-11-04
Metrics
Views/Downloads
  • Abstract
    1151
  • PDF
    210
Further information

How to Cite

Ziasistani, N., Meana-Fernández, A., & Gutierrez-Trashorras, A. J. (2025). Energy Performance Assessment: Impact of Blind and Shading on Double Skin Facade Performance. Anales de Edificación, 11(2), 46-49. https://doi.org/10.20868/ade.2025.5567

Most read articles by the same author(s)