Calculations of surface areas and ratios of minimum houses: the case of Barraca Murciana

Authors

DOI:

https://doi.org/10.20868/ade.2025.5640

Keywords:

Minimum house, murcian barrack, minimal surface, minimum ratio

Abstract

Falls from height during building construction are the leading cause of serious and fatal accidents in the construction sector and industry at large. During the usage and maintenance phases of buildings, this type of accident also results in a high incidence of injuries. The most used system to prevent such risks is the installation of safety guardrails.
Focusing on the prevention of fall risks in buildings during their usage and maintenance stages, in order for guardrails to effectively serve their protective function, they must meet a set of geometric and mechanical requirements. These include ensuring that their dimensions prevent individuals from bypassing them and that the systems are sufficiently resistant to withstand the force exerted by leaning or impacting individuals or objects.
This study compares the regulatory standards used in the United States (IBC and OSHA) and in Spain (CTE) concerning guardrails intended to prevent falls in buildings during their usage and maintenance phases.
The results reveal significant differences in the requirements imposed by each country, showing that for guardrails with a post spacing of less than 2.44 meters, U.S. regulations are more stringent than those of Spain

Downloads

Download data is not yet available.

References

1. Caravante, Francisco de Borja (2023). Ordenanza Municipal del Ayuntamiento de Madrid, aprobada el 17 de julio 2023.

2. Moya, Luis (2007). Manual VR : “Vivienda reducida”, (Moya, 2007, pp. 77-78). Editor y coordinador D. Luis Moya , capítulo “Análisis del objeto”. Autor D. Emilio Ontiveros

3. Narváez, Rocío (2018). Trabajo final de grado de Dª Roció Narváez : “ Vivienda mínima del siglo XXI: soluciones en Holanda y Japón”, trabajo presentado en la Escuela de Arquitectura de Madrid,

4. “Normas técnicas de diseño y calidad” (1976). Normativa para Viviendas Sociales publicada por el Ministerio de la Vivienda,

5. Romero, Julio (2016). Editorial ARREVOL- Julio A. Romero Alonso, publicado el 21 marzo 2016.

6. Steegmann, David (1986). “Las medidas de la vivienda” .Colegio Arquitectos de Cataluña - Barcelona Unión International Organismos Familiares (1959). (U.I.O.F., p.121).

Downloads

Published

2025-12-31
Metrics
Views/Downloads
  • Abstract
    394
  • pdf
    560
Further information

How to Cite

Pina-Ruiz, P., & Gil-López, T. (2025). Calculations of surface areas and ratios of minimum houses: the case of Barraca Murciana. Anales de Edificación, 11(3), 31-36. https://doi.org/10.20868/ade.2025.5640

Most read articles by the same author(s)